1064nm Single Mode Dual Fiber Collimator / Fiber optic focuser

The 1064nm SM Dual Fiber Collimator is the basic element for in-line fiber optics components, such as Circulators and WDM. It has low PDL, low insertion and high return loss. The unique processing and high-quality AR coating also enable this collimator to handle high power.

Features

  • Low Insertion Loss
  • Compact Design
  • Wide Operating Wavelength
  • High Reliability and Stability

Applications

  • Circulators
  • WDM
  • Coupler
  • Signal Processing

The 1064nm SM Dual Fiber Collimator is the basic element for in-line fiber optics components, such as Circulators and WDM. It has low PDL, low insertion and high return loss. The unique processing and high-quality AR coating also enable this collimator to handle high power.

If you do not see a standard Fiber Collimator that meets your needs, we welcome the opportunity to review your desired specification and quote a custom Fiber Collimator. Requests for custom fiber pigtails, different wavelengths and handling power of operation or other specific needs will be readily addressed.
Single Fiber Collimator / Fiber optic focuser

Performance Specifications

Parameter Unit Value
Operating wavelength (λc) nm 980,1030,1064,1150
Operating wavelength range nm ±50
Working Type Transmission Reflection
Working Distance mm 5~10 11~30 31~50 0mm for G-lens,2.4mm for C-lens
Max. Insertion Loss (λc) dB 0.30 0.40 0.50 0.30
Waist Beam Diameter mm ~0.42
Max. PDL dB 0.15
Min. Return Loss dB 55
Fiber Type 1060-XP
Max. Power Handling W 0.5, 1, 3, 5, 10
Operating temperature -5~+70
Storage temperature -40~+85
Dimension mm Φ3.2×10(Metal holder) or Φ2.78×9.0 (Glass tube)
  1. The specifications are w/o connector. Other lens sizes can also be customized according to requirements.
  2. For devices with connectors, IL will be 0.3dB higher, RL will be 5dB lower. Power transmits through the connector less than 2W.Measured at the alignment wavelength at 1/2 working distance.
  3. Waist Beam Diameter is measured at the alignment wavelength at 1/2 working distance. The beam diameter of the finished collimator varies when used at different working distances.
  4. When purchasing the collimator, please inform us whether it is used alone or in pairing. If paired, we will pack and ship the paired ones together.

Single Mode Dual Fiber Collimator

Package Dimension

Fiber Collimator / Fiber optic focuser

PS: The above are only typical dimensions, and the size of different working distances and spot sizes may vary.

Order information

P/N: COLL-D-②-③-④-⑤-⑥-⑦-⑧-⑨ (D: Dual fiber)

When you inquire, please provide the correct P/N number according to our ordering information, and attach the appropriate description would be better. If need any connector, we do not recommend choosing a 250μm bare fiber pigtail.
Wavelength
Working Distance
Power Handling
Working Type
Lens Type
Pigtails Diameter
Fiber Length
Connectors
Dimension
98:980nm
30:1030nm
64:1064nm
XX: Others
0: 0mm
5: 5mm
10:10mm
L:<0.5W
1:1W
3:3W
5:5W
T:Transmission
R:Reflection
C: C-lens
G: G-lens
25:250μm bare fiber
90:900μm Loose Fiber
XX: Others
10:1.0m
13:1.3m
15:1.5m
20:2.0m
XX: Others
00: None
FP: FC/PC
FA: FC/APC
SA: SC/APC
LA: LC/APC
XX: Others
3.2×10
2.78×9
Part Number Example: COLL-D-64-5-L-T-C-25-10-00-2.78X9

Description: 1064nm SM Dual Fiber Collimator, 5mm working distance ,0.5W hand power, Transmission type, C lens, 1060-XP fiber, bare fiber, 1.0m fiber length, and no connector, package dimension:2.78x9mm.Used in pairing.

Ordering Information for Custom Parts:

If you need to customize other specifications, please provide detailed description for your requirement.

Some reminders about collimators

2000nm Polarization Maintaining Single Fiber Collimator

 

1.Definition of working distance:
If used for pairing, it is the distance between two lenses.
If used alone, it is twice the distance between the lens and the target object.

 

2. Waist Beam Diameter: Ideally, it mostly refers to the spot diameter at the waist position (1/2 working distance).

3.Once the C-lens collimator is produced, the waist position has already been fixed, so measuring the spot diameter at different positions will have different values waist beam diameter. So the C-lens collimator cannot be considered a true collimator, it can only be considered a type of focusing device. Some parameters of the collimator, such as divergence angle, focal length, etc., are not applicable to C-lens collimators. When we make conventional collimators, we only consider the working distance, and the spot diameter is generally less than 0.5mm, unless we design C-lenses separately.

4.Back Focal Length: The distance between the lens and the end-cap(glass ferrule). By changing the back focal length of C-lens, the position of the waist can be adjusted within a certain range, resulting in different working distances.

back focal length